It is boiler water additive. It breaks the crystalline structure of lime-forming minerals in the water and amorphizes them and prevents them from sticking to the boiler and pipe surface. Thanks to the oxygen receptors included, it provides protection against corrosion on the boiler surface and pipe surface. It is sufficient for boiler water conditioning program. Does not require additional products.
Method of Use:
It is dosed to the boiler suction line, condensate tank or directly to the boiler with a dosing pump. The first dosage amount for a boiler that has not used conditioning chemicals before is 400 grams for 1 ton of boiler water. Then, it is dosed 100 - 200 grams for every 1 ton of water.
Recommended Values for Main Machine Water:
P.Alkalinity: 100 – 300 ppm
pH : 9 – 10,5
Chloride : < 300 ppm
If chloride and p.alkalinity values are greater than recommended, the vessel should be adjusted.
Physical Properties:
Appearance : Light yellow liquid
Density : 1,00 – 1,10 gr/cm3
pH : 7 – 9
Flash Point : None
Corrosive Effect : In pure contact, it can have a corrosive effect on all kinds of metals.